- 1800 5722 294
- contactus@industrialelectrics.com
- Plot No. 105, GNIDA,Greater Noida West, UP 201310
KVVS Elevator cables are manufactured with the following material and properties:
|
Description
|
Data
|
|
|---|---|---|
|
Type (CENLEC) code
|
HOSVVHE-F
|
|
|
Reference standard
|
EN 50214 & IEC 60227 Part 6
|
|
|
Application
|
Used as Pendant Lif/Elevator Cables for Low rise & Low speed up to 50meter & 16 mis, with easy communication/signaling norms. |
|
|
Special Feature
|
Online quality Extrusion Knurling enable cable to proper grip over pulleys. |
|
|
Voltage Rating
|
300/500V
|
|
|
Temperature rating
|
-20+70°C |
|
|
|
Min. Bending radius
|
5xD (HY)
|
|
|
Conductor
|
20x 0.75mm2
|
20x 0.50mm2
|
|
Conductor Material
|
Plain Copper Wires
|
Tinned Copper Wires
|
|
Conductor Construction
|
24/0.20mm (Class 5 IEC 60228)
|
16/0.20mm (Class 5 IEC 60228)
|
|
Max DC Resistance @20°C Ohm/km
|
26.00 Ohm/Km
|
40.1 Ohm/Km
|
|
Insulation
|
Extruded PVC
|
Extruded PE
|
|
Material
|
PVC {Type Ti2 EN 50363-3}
|
PE {LDPEEN 50290-2- 23)
|
|
Minimum Insulation Thickness ( mm)
|
0.38mm
|
0.38mm
|
|
Core Identification
|
Black 1-19 nos printed & YIG
|
Pair: Blue & White; Pair#2:Orange & White |
|
Twisting Pairs
|
NA
|
22 (twisted 10 twists/mtr min)
|
|
Screening (Shield)
|
N/A
|
Individual pair with ATC Wire braiding with 70% coverage |
|
Cable Assembly
|
20 Cores + 2 Screened pairs laid parallel with groups. (5x4) +2x2 |
|
|
Rip Cord
|
Cotton Threads are place in each group to strip out sheath.
|
|
|
Sheath Thickness- Minimum
|
1.00mm
|
|
|
Sheath Overall Diameter - Maximum
|
58 +/-2(Width) x 6 (Ht) mm
|
|
|
Sheath Material
|
PVC {Type TM2: EN 50363-4-1/ Type STSIEC 60227-1}
|
|
|
Sheath Color
|
Black
|
|
|
High Voltage Test
|
2KV AC for 15 Minutes (for 0.50sqmm 1Kv-1 Minute)
|
|
|
Insulation Resistance @ 70°C
|
>0.012 MOhm/km
|
|
|
Impact Test at -5°C
|
Pass as per EN 60811
|
|
|
Passed flexing Test — 60000 forward - backward cycles with 6AMp current240V followed by Voltage test of 2000V. |
Passed flexing Test — 60000 forward - backward cycles with 6AMp current240V followed by Voltage test of 2000V. |
|
|
Fire Test
|
Flame retardant as per [EC 6033-12
|
|
|
Resistance to
|
Oil, Water, Abrasion, Flame, Chemicals.
|
|
|
Print Marking
|
KVVS ( 20X0.75Sqmm + 2X2X0.50SQMM | Shielded) FLAT TRAVELLING CABLE mmiyy mir mark | |
|
|
Packing
|
500 mir drum length or as per agreement between Rollflex & customer |
|